31 HIGH
PRESSURE SWITCH FAULT - Indicates high pressure switch is
|
closed at call,
or in low heat,
|
|
|
or fails to close
after call, or opens in high heat.
|
|
|
Check for: -
Plugged condensate drain.
|
|
|
- Water in vent
piping, possibly sagging pipe.
|
|
|
- Improper
pressure switch wiring or pressure switch tubing connections.
|
|
|
- |
Failed or
"Out-of-Calibration" pressure switches.
|
|
|
32 LOW
PRESSURE SWITCH FAULT - Indicates low pressure switch is
|
|
closed at call,
or fails to close
|
|
|
after call, or
opens during operation.
|
|
|
Check for: -
Plugged condensate drain.
|
|
|
- Water in vent
piping, possibly sagging pipe.
|
|
|
- Improper
pressure switch wiring or pressure switch tubing connections.
|
|
|
- Failed or
"Out-of-Calibration" pressure switches
|
|